ARM: LPC32xx: Add PWM support
[cascardo/linux.git] / drivers / net / ethernet / intel / Kconfig
1 #
2 # Intel network device configuration
3 #
4
5 config NET_VENDOR_INTEL
6         bool "Intel devices"
7         default y
8         depends on PCI || PCI_MSI || ISA || ISA_DMA_API || ARM || \
9                    ARCH_ACORN || MCA || MCA_LEGACY || SNI_RM || SUN3 || \
10                    GSC || BVME6000 || MVME16x || \
11                    (ARM && ARCH_IXP4XX && IXP4XX_NPE && IXP4XX_QMGR) || \
12                    EXPERIMENTAL
13         ---help---
14           If you have a network (Ethernet) card belonging to this class, say Y
15           and read the Ethernet-HOWTO, available from
16           <http://www.tldp.org/docs.html#howto>.
17
18           Note that the answer to this question doesn't directly affect the
19           kernel: saying N will just cause the configurator to skip all
20           the questions about Intel cards. If you say Y, you will be asked for
21           your specific card in the following questions.
22
23 if NET_VENDOR_INTEL
24
25 config E100
26         tristate "Intel(R) PRO/100+ support"
27         depends on PCI
28         select NET_CORE
29         select MII
30         ---help---
31           This driver supports Intel(R) PRO/100 family of adapters.
32           To verify that your adapter is supported, find the board ID number
33           on the adapter. Look for a label that has a barcode and a number
34           in the format 123456-001 (six digits hyphen three digits).
35
36           Use the above information and the Adapter & Driver ID Guide at:
37
38           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
39
40           to identify the adapter.
41
42           For the latest Intel PRO/100 network driver for Linux, see:
43
44           <http://www.intel.com/p/en_US/support/highlights/network/pro100plus>
45
46           More specific information on configuring the driver is in
47           <file:Documentation/networking/e100.txt>.
48
49           To compile this driver as a module, choose M here. The module
50           will be called e100.
51
52 config E1000
53         tristate "Intel(R) PRO/1000 Gigabit Ethernet support"
54         depends on PCI
55         ---help---
56           This driver supports Intel(R) PRO/1000 gigabit ethernet family of
57           adapters.  For more information on how to identify your adapter, go
58           to the Adapter & Driver ID Guide at:
59
60           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
61
62           For general information and support, go to the Intel support
63           website at:
64
65           <http://support.intel.com>
66
67           More specific information on configuring the driver is in
68           <file:Documentation/networking/e1000.txt>.
69
70           To compile this driver as a module, choose M here. The module
71           will be called e1000.
72
73 config E1000E
74         tristate "Intel(R) PRO/1000 PCI-Express Gigabit Ethernet support"
75         depends on PCI && (!SPARC32 || BROKEN)
76         select CRC32
77         ---help---
78           This driver supports the PCI-Express Intel(R) PRO/1000 gigabit
79           ethernet family of adapters. For PCI or PCI-X e1000 adapters,
80           use the regular e1000 driver For more information on how to
81           identify your adapter, go to the Adapter & Driver ID Guide at:
82
83           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
84
85           For general information and support, go to the Intel support
86           website at:
87
88           <http://support.intel.com>
89
90           To compile this driver as a module, choose M here. The module
91           will be called e1000e.
92
93 config IGB
94         tristate "Intel(R) 82575/82576 PCI-Express Gigabit Ethernet support"
95         depends on PCI
96         ---help---
97           This driver supports Intel(R) 82575/82576 gigabit ethernet family of
98           adapters.  For more information on how to identify your adapter, go
99           to the Adapter & Driver ID Guide at:
100
101           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
102
103           For general information and support, go to the Intel support
104           website at:
105
106           <http://support.intel.com>
107
108           More specific information on configuring the driver is in
109           <file:Documentation/networking/e1000.txt>.
110
111           To compile this driver as a module, choose M here. The module
112           will be called igb.
113
114 config IGB_DCA
115         bool "Direct Cache Access (DCA) Support"
116         default y
117         depends on IGB && DCA && !(IGB=y && DCA=m)
118         ---help---
119           Say Y here if you want to use Direct Cache Access (DCA) in the
120           driver.  DCA is a method for warming the CPU cache before data
121           is used, with the intent of lessening the impact of cache misses.
122
123 config IGB_PTP
124         bool "PTP Hardware Clock (PHC)"
125         default y
126         depends on IGB && PTP_1588_CLOCK
127         ---help---
128           Say Y here if you want to use PTP Hardware Clock (PHC) in the
129           driver.  Only the basic clock operations have been implemented.
130
131           Every timestamp and clock read operations must consult the
132           overflow counter to form a correct time value.
133
134 config IGBVF
135         tristate "Intel(R) 82576 Virtual Function Ethernet support"
136         depends on PCI
137         ---help---
138           This driver supports Intel(R) 82576 virtual functions.  For more
139           information on how to identify your adapter, go to the Adapter &
140           Driver ID Guide at:
141
142           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
143
144           For general information and support, go to the Intel support
145           website at:
146
147           <http://support.intel.com>
148
149           More specific information on configuring the driver is in
150           <file:Documentation/networking/e1000.txt>.
151
152           To compile this driver as a module, choose M here. The module
153           will be called igbvf.
154
155 config IXGB
156         tristate "Intel(R) PRO/10GbE support"
157         depends on PCI
158         ---help---
159           This driver supports Intel(R) PRO/10GbE family of adapters for
160           PCI-X type cards. For PCI-E type cards, use the "ixgbe" driver
161           instead. For more information on how to identify your adapter, go
162           to the Adapter & Driver ID Guide at:
163
164           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
165
166           For general information and support, go to the Intel support
167           website at:
168
169           <http://support.intel.com>
170
171           More specific information on configuring the driver is in
172           <file:Documentation/networking/ixgb.txt>.
173
174           To compile this driver as a module, choose M here. The module
175           will be called ixgb.
176
177 config IXGBE
178         tristate "Intel(R) 10GbE PCI Express adapters support"
179         depends on PCI && INET
180         select MDIO
181         ---help---
182           This driver supports Intel(R) 10GbE PCI Express family of
183           adapters.  For more information on how to identify your adapter, go
184           to the Adapter & Driver ID Guide at:
185
186           <http://support.intel.com/support/network/adapter/pro100/21397.htm>
187
188           For general information and support, go to the Intel support
189           website at:
190
191           <http://support.intel.com>
192
193           To compile this driver as a module, choose M here. The module
194           will be called ixgbe.
195
196 config IXGBE_HWMON
197         bool "Intel(R) 10GbE PCI Express adapters HWMON support"
198         default y
199         depends on IXGBE && HWMON && !(IXGBE=y && HWMON=m)
200         ---help---
201           Say Y if you want to expose the thermal sensor data on some of
202           our cards, via a hwmon sysfs interface.
203
204 config IXGBE_DCA
205         bool "Direct Cache Access (DCA) Support"
206         default y
207         depends on IXGBE && DCA && !(IXGBE=y && DCA=m)
208         ---help---
209           Say Y here if you want to use Direct Cache Access (DCA) in the
210           driver.  DCA is a method for warming the CPU cache before data
211           is used, with the intent of lessening the impact of cache misses.
212
213 config IXGBE_DCB
214         bool "Data Center Bridging (DCB) Support"
215         default n
216         depends on IXGBE && DCB
217         ---help---
218           Say Y here if you want to use Data Center Bridging (DCB) in the
219           driver.
220
221           If unsure, say N.
222
223 config IXGBE_PTP
224         bool "PTP Clock Support"
225         default n
226         depends on IXGBE && PTP_1588_CLOCK
227         ---help---
228           Say Y here if you want support for 1588 Timestamping with a
229           PHC device, using the PTP 1588 Clock support. This is
230           required to enable timestamping support for the device.
231
232           If unsure, say N.
233
234 config IXGBEVF
235         tristate "Intel(R) 82599 Virtual Function Ethernet support"
236         depends on PCI_MSI
237         ---help---
238           This driver supports Intel(R) 82599 virtual functions.  For more
239           information on how to identify your adapter, go to the Adapter &
240           Driver ID Guide at:
241
242           <http://support.intel.com/support/network/sb/CS-008441.htm>
243
244           For general information and support, go to the Intel support
245           website at:
246
247           <http://support.intel.com>
248
249           More specific information on configuring the driver is in
250           <file:Documentation/networking/ixgbevf.txt>.
251
252           To compile this driver as a module, choose M here. The module
253           will be called ixgbevf.  MSI-X interrupt support is required
254           for this driver to work correctly.