net: hns: bug fix of ge reset sequence
authorQianqian Xie <xieqianqian@huawei.com>
Tue, 21 Jun 2016 03:56:21 +0000 (11:56 +0800)
committerDavid S. Miller <davem@davemloft.net>
Tue, 21 Jun 2016 08:51:54 +0000 (04:51 -0400)
The bit fileds of PPE reset register are different between HNS v1 and
HNS v2, but the current procedure just only match HNS v1. Here is a
patch to fix it.

Signed-off-by: Kejian Yan <yankejian@huawei.com>
Signed-off-by: Qianqian Xie <xieqianqian@huawei.com>
Signed-off-by: Yisen Zhuang <Yisen.Zhuang@huawei.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/ethernet/hisilicon/hns/hns_dsaf_misc.c

index 96cb628..09e60d6 100644 (file)
@@ -271,7 +271,11 @@ static void hns_dsaf_ge_srst_by_port(struct dsaf_device *dsaf_dev, u32 port,
                }
        } else {
                reg_val_1 = 0x15540 << dsaf_dev->reset_offset;
-               reg_val_2 = 0x100 << dsaf_dev->reset_offset;
+
+               if (AE_IS_VER1(dsaf_dev->dsaf_ver))
+                       reg_val_2 = 0x100 << dsaf_dev->reset_offset;
+               else
+                       reg_val_2 = 0x40 << dsaf_dev->reset_offset;
 
                if (!dereset) {
                        dsaf_write_sub(dsaf_dev, DSAF_SUB_SC_GE_RESET_REQ1_REG,