s390/hmcdrv: fix interrupt registration
authorHeiko Carstens <heiko.carstens@de.ibm.com>
Mon, 17 Aug 2015 05:56:20 +0000 (07:56 +0200)
committerMartin Schwidefsky <schwidefsky@de.ibm.com>
Wed, 19 Aug 2015 08:40:17 +0000 (10:40 +0200)
The z/VM driver sets bit "63-22" in control register zero to one in order
to enable the CP Service interrupt (0x2603). However the irq subclass mask
that normally corresponds to the CP Service interrupt is
"63-54" (== "63-22-32").

So it looks like the author read the documentation with the 32 bit sized
cr0 register bit positions (== 22), but didn't realize that bit numbers
change, if applied to a 64 bit register (== 54) due to the numbering
scheme.

Also use irq_subclass_register() instead if ctl_set_bit() since multiple
services depend on the service signal subclass mask, which is the correct
bit. This also explains why nobody noticed the bug, since the bit is always
enabled anyway (e.g. pfault).

Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Reviewed-by: Hendrik Brueckner <brueckner@linux.vnet.ibm.com>
Acked-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
drivers/s390/char/diag_ftp.c

index 9388963..12db8db 100644 (file)
@@ -223,7 +223,7 @@ int diag_ftp_startup(void)
        if (rc)
                return rc;
 
-       ctl_set_bit(0, 63 - 22);
+       irq_subclass_register(IRQ_SUBCLASS_SERVICE_SIGNAL);
        return 0;
 }
 
@@ -232,6 +232,6 @@ int diag_ftp_startup(void)
  */
 void diag_ftp_shutdown(void)
 {
-       ctl_clear_bit(0, 63 - 22);
+       irq_subclass_unregister(IRQ_SUBCLASS_SERVICE_SIGNAL);
        unregister_external_irq(EXT_IRQ_CP_SERVICE, diag_ftp_handler);
 }