HID: rmi: fix masks for x and w_x data
authorAndrew Duggan <aduggan@synaptics.com>
Thu, 15 May 2014 20:52:29 +0000 (13:52 -0700)
committerJiri Kosina <jkosina@suse.cz>
Fri, 16 May 2014 09:12:46 +0000 (11:12 +0200)
The F11 data in the HID report contains four bits of data for w_x and the least significant bits
of x. Currently only the first three bits are being used which is resulting in small jumps in
the position data on the x axis and in the w_x data.

Signed-off-by: Andrew Duggan <aduggan@synaptics.com>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@redhat.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
drivers/hid/hid-rmi.c

index 7ebdc96..c529b03 100644 (file)
@@ -277,9 +277,9 @@ static void rmi_f11_process_touch(struct rmi_data *hdata, int slot,
        input_mt_report_slot_state(hdata->input, MT_TOOL_FINGER,
                        finger_state == 0x01);
        if (finger_state == 0x01) {
-               x = (touch_data[0] << 4) | (touch_data[2] & 0x07);
+               x = (touch_data[0] << 4) | (touch_data[2] & 0x0F);
                y = (touch_data[1] << 4) | (touch_data[2] >> 4);
-               wx = touch_data[3] & 0x07;
+               wx = touch_data[3] & 0x0F;
                wy = touch_data[3] >> 4;
                wide = (wx > wy);
                major = max(wx, wy);