ARM: dts: silk: Fix W=1 dtc warnings
[cascardo/linux.git] / arch / arm / boot / dts / exynos5422-cpu-thermal.dtsi
1 /*
2  * Device tree sources for Exynos5422 thermal zone
3  *
4  * Copyright (c) 2015 Lukasz Majewski <l.majewski@samsung.com>
5  *                      Anand Moon <linux.amoon@gmail.com>
6  *
7  * This program is free software; you can redistribute it and/or modify
8  * it under the terms of the GNU General Public License version 2 as
9  * published by the Free Software Foundation.
10  *
11  */
12
13 #include <dt-bindings/thermal/thermal.h>
14
15 / {
16         thermal-zones {
17                 cpu0_thermal: cpu0-thermal {
18                         thermal-sensors = <&tmu_cpu0 0>;
19                         polling-delay-passive = <250>;
20                         polling-delay = <0>;
21                         trips {
22                                 cpu_alert0: cpu-alert-0 {
23                                         temperature = <50000>; /* millicelsius */
24                                         hysteresis = <5000>; /* millicelsius */
25                                         type = "active";
26                                 };
27                                 cpu_alert1: cpu-alert-1 {
28                                         temperature = <60000>; /* millicelsius */
29                                         hysteresis = <5000>; /* millicelsius */
30                                         type = "active";
31                                 };
32                                 cpu_alert2: cpu-alert-2 {
33                                         temperature = <70000>; /* millicelsius */
34                                         hysteresis = <5000>; /* millicelsius */
35                                         type = "active";
36                                 };
37                                 cpu_crit0: cpu-crit-0 {
38                                         temperature = <120000>; /* millicelsius */
39                                         hysteresis = <0>; /* millicelsius */
40                                         type = "critical";
41                                 };
42                                 /*
43                                  * Exyunos542x support only 4 trip-points
44                                  * so for these polling mode is required.
45                                  * Start polling at temperature level of last
46                                  * interrupt-driven trip: cpu_alert2
47                                  */
48                                 cpu_alert3: cpu-alert-3 {
49                                         temperature = <70000>; /* millicelsius */
50                                         hysteresis = <10000>; /* millicelsius */
51                                         type = "passive";
52                                 };
53                                 cpu_alert4: cpu-alert-4 {
54                                         temperature = <85000>; /* millicelsius */
55                                         hysteresis = <10000>; /* millicelsius */
56                                         type = "passive";
57                                 };
58
59                         };
60                         cooling-maps {
61                                 map0 {
62                                      trip = <&cpu_alert0>;
63                                      cooling-device = <&fan0 0 1>;
64                                 };
65                                 map1 {
66                                      trip = <&cpu_alert1>;
67                                      cooling-device = <&fan0 1 2>;
68                                 };
69                                 map2 {
70                                      trip = <&cpu_alert2>;
71                                      cooling-device = <&fan0 2 3>;
72                                 };
73                                 /*
74                                  * When reaching cpu_alert3, reduce CPU
75                                  * by 2 steps. On Exynos5422/5800 that would
76                                  * be: 1500 MHz and 1100 MHz.
77                                  */
78                                 map3 {
79                                      trip = <&cpu_alert3>;
80                                      cooling-device = <&cpu0 0 2>;
81                                 };
82                                 map4 {
83                                      trip = <&cpu_alert3>;
84                                      cooling-device = <&cpu4 0 2>;
85                                 };
86
87                                 /*
88                                  * When reaching cpu_alert4, reduce CPU
89                                  * further, down to 600 MHz (11 steps for big,
90                                  * 7 steps for LITTLE).
91                                  */
92                                 map5 {
93                                      trip = <&cpu_alert4>;
94                                      cooling-device = <&cpu0 3 7>;
95                                 };
96                                 map6 {
97                                      trip = <&cpu_alert4>;
98                                      cooling-device = <&cpu4 3 11>;
99                                 };
100                         };
101                 };
102         };
103 };