datapath-windows: Return success for already existing WFP objects
authorSorin Vinturis <svinturis@cloudbasesolutions.com>
Thu, 18 Jun 2015 18:37:13 +0000 (18:37 +0000)
committerBen Pfaff <blp@nicira.com>
Tue, 23 Jun 2015 18:45:43 +0000 (11:45 -0700)
There are cases when the WFP callout or sublayer, being persistent
objects, already exists when we try to register the OVS callout. In
this cases, when trying to add again these WFP objects the return code
is STATUS_FWP_ALREADY_EXISTS, which we are interpreting as an error.
This is incorrect and this patch changes that.

Signed-off-by: Sorin Vinturis <svinturis@cloudbasesolutions.com>
Reported-by: Sorin Vinturis <svinturis@cloudbasesolutions.com>
Reported-at: https://github.com/openvswitch/ovs-issues/issues/84
Signed-off-by: Ben Pfaff <blp@nicira.com>
datapath-windows/ovsext/TunnelFilter.c

index 08cc13f..231750e 100644 (file)
@@ -414,7 +414,12 @@ OvsTunnelRegisterDatagramDataCallouts(const GUID *layerKey,
 
     status = FwpmCalloutAdd(gEngineHandle, &mCallout, NULL, NULL);
     if (!NT_SUCCESS(status)) {
-        goto Exit;
+        if (STATUS_FWP_ALREADY_EXISTS != status) {
+            OVS_LOG_ERROR("Failed to add WFP callout, status: %x.",
+                          status);
+            goto Exit;
+        }
+        status = STATUS_SUCCESS;
     }
 
 Exit:
@@ -459,7 +464,11 @@ OvsTunnelRegisterCallouts(VOID *deviceObject)
 
     status = FwpmSubLayerAdd(gEngineHandle, &OvsTunnelSubLayer, NULL);
     if (!NT_SUCCESS(status)) {
-        goto Exit;
+        if (STATUS_FWP_ALREADY_EXISTS != status) {
+            OVS_LOG_ERROR("Failed to add WFP sublayer, status: %x.",
+                          status);
+            goto Exit;
+        }
     }
 
     /* In order to use this callout a socket must be opened. */